Consecutive frequency and Convenient zero function | The LCR-6000 series, within the provided frequency range, features consecutive and adjustable frequency capability which allows users to conduct measurement and analysis on components with the most genuine frequency requirements. For OPEN/SHORT fixture compensation function, the LCR-6000 series is equipped with full frequency range zero and spot zero selections. After executing full frequency range zero, users, under the conditions of not turning off the power and not changing test fixture, can freely change test frequency for the LCR-6000 series to execute component measurements that tremendously saves time in repeatedly zeroing test fixture after changing frequency. | ![01]() Consecutive and adjustable frequency Freely input frequency within provided frequency range
| ![02]() Selectable fixture zeroing methods Full frequency range zero or spot zero
| Rich and diverse information display | The measurement result display of the LCR-6000 series not only reveals primary and secondary measurement parameters but also includes two monitoring parameters. Therefore, four DUT related parameters can be simultaneously shown on the display screen to save time if repeated measurements are required. With respect to display screen, the LCR-6000 series features diverse display to meet users’ observation requirements. For instance, MEAS display shows setting parameters and measurement results at the same time; ENLARGE display focuses on measurement results and PASS/FAIL judgment is available, which is conducive to assist engineers to swiftly obtain the validity of measurement results. | ![01]() MEAS display Parameter setting and four measurement parameters
| ![02]() ENLARGE display Enlarge measurement results and include PASS/FAIL judgment
| 10 points listed tests and PC software | The LCR-6000 series provides the 10 points listed test function, which allows users to define a set of DUT measurement parameters (such as Cs- Rs) and to set 10 test criteria of category (either by frequency or by voltage or by current) but different values to conduct measurements. Through this function, users can rapidly and clearly obtain DUT’s characteristic variation trend to determine the adaptability of DUT’s practical applications. The measurement results can be recorded directly in the internal memory and be transferred to the PC through USB. The LCR-6000 series also provides free PC software (maximum 1,000 points listed tests) in order to satisfy users’ analytical requirements on delicate variation. | ![01]() Listed tests Variation criteria based upon frequency or voltage/current
| ![02]() On software ─ characteristic curve Provide more delicate characteristic variation trend
| Diverse ancillary measurement functions | To satisfy the diverse measurement application requirements for different components and materials, the LCR-6000 series collocates with many auxiliary measurement functions. For capacitor measurement, Automatic Level Control (ALC) is mainly for component which requires a constant or rated test voltage such as multi-layer ceramic capacitor (MLCC). An internal D.C. bias voltage (±2.5V, internal) is allowing simulating A.C. and D.C. coexistence to learn capacitance variation. For inductor measurement, the D.C. resistance measurement function is to validate D.C. resistance characteristics. Additional, the LCZ function is to quickly identify components ’characteristics. When the function is activated, the LCR-6000 series will automatically determine DUTs’ characteristics and reveal the optimum parameters to show the measurement results. | ![01]() Automatic level control Ideal for measuring components with voltage requirements
| ![02]() Internal bias (±2.5V adjustable) Ideal for capacitive components’ characteristic tests
| ![01]() D.C. resistance measurement Ideal for inductive components’ D.C. characteristics verification
| | Standard Interface | For interface connectivity, the LCR-6000 series comes equipped with handler interface and RS-232C interface. Handler outputs 10 BIN (9BIN, AUX: 1BIN) sorting results that is best for external connection control, for instance, connecting to a sorting machine to conduct components’ sorting operation. RS-232C is suitable for remote control and measurement results retrieval. The PC gives commands to control settings or to read measurement results so as to achieve the requirements of verifying automotive applications. | ![02]()
|
|
|
| TEST FREQUENCY | | LCR-6300: 10Hz~300kHz(±0.01%) (4 digits resolution) LCR-6200: 10Hz~200kHz(±0.01%) (4 digits resolution) LCR-6100: 10Hz~100kHz(±0.01%) (4 digits resolution) LCR-6020: 10Hz~ 20kHz(±0.01%) (4 digits resolution) LCR-6002: 10Hz~ 2kHz(±0.01%) (4 digits resolution) | OUTPUT IMPEDANCE | | 30Ω / 50Ω / 100Ω selectable | BASIC ACCURACY | Slow / Med | 0.05% | Fast | 0.1% | TEST SPEED | | FAST:25ms / MED:100ms / SLOW:333ms | TEST SIGNAL LEVELS | Voltage | 10.00mV- 2.00V (±10%) CV :10.00mV- 2.00V(±6%) | Current | 100.0uA- 20.00mA (±10%) CC :100.0uA- 20.00mA(±6%) (@2VMax) | DC BIAS | Internal | ±2.5V (0.5%+0.005V) | DISPLAYRANGE | R, X, |Z| G, B, |Y| L C D Q θd θr DCR Δ% | 0.00001Ω ~ 99.9999MΩ 0.01nS ~ 999.999S 0.00001uH ~ 9999.99H 0.00001pF ~ 9999.99mF 0.00001 ~ 9.99999 0.00001 ~ 99999.9 -179.999° ~ 179.999° -3.14159 ~ 3.14159 0.00001Ω ~ 99.9999MΩ -99999% ~ 99999% | TEST MODE | 16 Combinations | Cs-Rs, Cs-D, Cp-Rp, Cp-D, Lp-Rp, Lp-Q, Ls-Rs, Ls-Q, Rs-Q, Rp-Q, R-X, Z-θr, Z-θd, Z-D, Z-Q, DCR | Monitor parameter (2 selectable) | Z, D, Q, Vac, Iac, Δ, Δ%, θr, θd, R, X, G, B, Y | LISTED MODE | | 10 steps | BIN FUNCTION | | Comparator (9BIN,AUX:1BIN) | MEMORY | INT – panel setting | 10 file name | INT – measured data | 10000 Data(.csv) | USB storage | 10 file name for setting, 9999 file name for data, 999 Log file for LCD screen | OTHER FUNCTION | Auto Level Control (ALC) | ON/OFF | Average | 1~256 times | Trigger | INT / MAN / EXT / BUS | Delay | 0ms~60s | Judgment | PASS / FAIL | Auto LCZ | ON / OFF | Screen Capture | Saving in to USB (Bmp form) | DISPLAY | | 3.5'LCD, RGB color (320x240) | INTERFACE | | RS-232(SCPI), Handler, USB Host | POWER SOURCE | | AC 90V-250V, 50-60Hz, Max. 30VA | DIMENSION & WEIGHT | | 265(W)x107(H)x312(D) mm, Approx.3kg |
|
| | 기본 악세사리 | 옵션 악세사리 | Safety Sheet x 1 Power Cord x 1 LCR-06A x 1 CD x 1(User manual / PC software) | LCR-05, Test Fixture for Axial & Radial Lead Components LCR-06A, Kelvin Clip Test Lead LCR-07, Test Fixture, Two-Wire with Alligator Clips LCR-08, Test Fixture (Tweezers) for SMD/Chip Components LCR-15, Test Fixture for SMD/Chip Components (0201 to 1812) LCR-16, Test Fixture – ±45V DC Bias Voltage Box LCR-17, Test Fixture – ±2.5ADC Bias Current Box GTL-232, RS-232C Cable, 9-pin Female to 9-pin, null Modem for Computer, Approx.2m |
|
| | 본체 (제품 가격은 사전 공지없이 변경될 수 있습니다)
| 품목 | 설명 | 가격 (VAT 별도) | LCR-6300 | 300kHz 고정밀 LCR 미터 | 3,155,000원 | LCR-6200 | 200kHz 고정밀 LCR 미터 | 2,783,000원 | LCR-6100 | 100kHz 고정밀 LCR 미터 | 2,455,000원 | LCR-6020 | 20kHz 고정밀 LCR 미터 | 2,088,000원 | LCR-6002 | 2kHz 고정밀 LCR 미터 | 1,375,000원 |
옵션 및 악세사리 (제품 가격은 사전 공지없이 변경될 수 있습니다)
| 품목 | 설명 | 가격 (VAT 별도) | LCR-15 | SMD/칩 부품 테스트 픽스쳐 (0201~1812) | 280,000원 | LCR-16 | 테스트 픽스쳐 (±45V DC 바이어스 전압 박스) | 712,000원 | LCR-17 | 테스트 픽스쳐 (±2.5A DC 바이어스 전류 박스) | 398,000원 |
|
|
|
TEST FREQUENCY | | LCR-6300: 10Hz~300kHz(±0.01%) (4 digits resolution) LCR-6200: 10Hz~200kHz(±0.01%) (4 digits resolution) LCR-6100: 10Hz~100kHz(±0.01%) (4 digits resolution) LCR-6020: 10Hz~ 20kHz(±0.01%) (4 digits resolution) LCR-6002: 10Hz~ 2kHz(±0.01%) (4 digits resolution) | OUTPUT IMPEDANCE | | 30Ω / 50Ω / 100Ω selectable | BASIC ACCURACY | Slow / Med | 0.05% | Fast | 0.1% | TEST SPEED | | FAST:25ms / MED:100ms / SLOW:333ms | TEST SIGNAL LEVELS | Voltage | 10.00mV- 2.00V (±10%) CV :10.00mV- 2.00V(±6%) | Current | 100.0uA- 20.00mA (±10%) CC :100.0uA- 20.00mA(±6%) (@2VMax) | DC BIAS | Internal | ±2.5V (0.5%+0.005V) | DISPLAYRANGE | R, X, |Z| G, B, |Y| L C D Q θd θr DCR Δ% | 0.00001Ω ~ 99.9999MΩ 0.01nS ~ 999.999S 0.00001uH ~ 9999.99H 0.00001pF ~ 9999.99mF 0.00001 ~ 9.99999 0.00001 ~ 99999.9 -179.999° ~ 179.999° -3.14159 ~ 3.14159 0.00001Ω ~ 99.9999MΩ -99999% ~ 99999% | TEST MODE | 16 Combinations | Cs-Rs, Cs-D, Cp-Rp, Cp-D, Lp-Rp, Lp-Q, Ls-Rs, Ls-Q, Rs-Q, Rp-Q, R-X, Z-θr, Z-θd, Z-D, Z-Q, DCR | Monitor parameter (2 selectable) | Z, D, Q, Vac, Iac, Δ, Δ%, θr, θd, R, X, G, B, Y | LISTED MODE | | 10 steps | BIN FUNCTION | | Comparator (9BIN,AUX:1BIN) | MEMORY | INT – panel setting | 10 file name | INT – measured data | 10000 Data(.csv) | USB storage | 10 file name for setting, 9999 file name for data, 999 Log file for LCD screen | OTHER FUNCTION | Auto Level Control (ALC) | ON/OFF | Average | 1~256 times | Trigger | INT / MAN / EXT / BUS | Delay | 0ms~60s | Judgment | PASS / FAIL | Auto LCZ | ON / OFF | Screen Capture | Saving in to USB (Bmp form) | DISPLAY | | 3.5'LCD, RGB color (320x240) | INTERFACE | | RS-232(SCPI), Handler, USB Host | POWER SOURCE | | AC 90V-250V, 50-60Hz, Max. 30VA | DIMENSION & WEIGHT | | 265(W)x107(H)x312(D) mm, Approx.3kg |
|